: Ensure the cabinet and iPendant are free of excessive dust, oil, or debris. Monthly Tasks
| Alarm Code | Meaning | Maintenance Action | |------------|---------|--------------------| | | Blown fuse on servo amp (FS1/FS2) | Check motor cable insulation resistance (should be >50MΩ at 500V megger). Replace amp if no short. | | SRVO-038 | Pulse mismatch — encoder battery loss | Replace battery. Perform Zero Position Mastering with a mastering gauge. | | SRVO-230 | Fan failure (chassis or PSU) | Replace fan. Run Air purge routine to clear dust from tachometer sensor. | | SRVO-292 | DCS safety relay fault | Check ES1/ES2 terminals on TB7. Replace safety relay (A16B-2300 series). | | SRVO-432 | CPU watchdog (watchdog timer WDT) | Corrupt software stack. Reload OS (Bootstrap from PCMCIA). Replace motherboard if persistent. | | SRVO-475 | Soft thermal overload (servo) | Dirty servo amp heat sink. Remove, clean with non-conductive brush, verify cooling paste on IGBT modules. | fanuc robot series r 30ib controller maintenance manual
Inspect the cable for frays and the screen for cracks. Quarterly Tasks (Every 3 Months) : Ensure the cabinet and iPendant are free